Power On Default Screen For Master Unit - KEPCO BOP 1000W Operator's Manual

High power bipolar power supply
Hide thumbs Also See for BOP 1000W:
Table of Contents

Advertisement

Slave Status Message
Displayed on Master Power Up Screen
(see Figure 2-9)
Ready
STANDBY
Powered OFF
Failed
Not Used
Unknown
If the master power-up screen is still displayed after 10 seconds, a slave was not properly rec-
ognized. Pressing
unit. Verify that the BITBUS cable is installed correctly. Verify that the slave has been properly
configured as a slave per step 1 above. Repeat step 3. If the power up screen still does not
revert to the power on default screen, refer to troubleshooting.
4. Adjust the limits to reflect the increased power capacity of the multiple unit combination as
follows:
a. From the main screen, press
b. From the General Setup menu, Highlight Max/Min Settings and press
restore defaults. Verify that the Max/Min settings reflect the multiple unit combination. For
example, for a parallel combination the values for +Current Max, –Current Min and ±Cur-
rent Protect Max/Min now reflect the total current of the parallel combination. Voltage val-
ues and limits reflect a series combination. For 2 X 2 and 3 X 2 combinations both current
and voltage are affected. NOTE: If desired, these limits may be lowered as described for a
standalone unit (see PAR. 3.3.4).
$
c. Press
return to the power-up screen
FIGURE 2-10.
2-22
TABLE 2-13. SLAVE STATUS MESSAGE DEFINITIONS
Unit is ready for operation.
If unit's FAULT indicator is off, hardware error has NOT been detected,
output is ready to be turned on
Unit is not responding to polls via BITBUS.
Unit's FAULT indicator is on to indicate a hardware error has been
detected.
Unit is not part of parallel configuration
Waiting for interface communication
%
or turning power off, then on again, reconfigures the unit as a standalone
%
to save the settings upon power-up, then

POWER ON DEFAULT SCREEN FOR MASTER UNIT

MEANING
to enter the General Setup Menu.
%
to exit the General Setup menu and
VOLTAGE
0.
0000
!
@
. Press
to
BOP HIPWR 080709