Power Supply
BOP 5-20DL
KEPCO BOP 5-20DL Manuals
Manuals and User Guides for KEPCO BOP 5-20DL. We have
1
KEPCO BOP 5-20DL manual available for free PDF download: Operator's Manual
KEPCO BOP 5-20DL Operator's Manual (70 pages)
BIPOLAR OPERATIONAL POWER SUPPLY
Brand:
KEPCO
| Category:
Power Supply
| Size: 1.38 MB
Table of Contents
Power Supply
1
Table of Contents
3
Section 1 - Introduction
9
Scope of Manual
9
General Description
9
Electrical Specifications, General
9
General Specifications
10
Output Range and Output Impedance
12
Static Specifications
13
Dynamic Specifications
14
Miscellaneous Features
14
Output Range
14
Rear Programming Features
15
Output ON-OFF Port
16
Output ON-OFF Port A2J211, Pin Assignments
17
Load Reactance
18
Remote Turn-Off
18
Circuit Breaker Shutdown Prevention (at Power Loss) Circuit
18
References
18
Series or Parallel Operation
18
Voltage Control Channel
19
Mode Switch
19
Current Control Channel
19
Bounding
19
Mode Lights
20
Remote Output ON-OFF LED
20
Standards
20
Mechanical Specifications
20
Equipment Supplied
20
Accessories
21
Safety
21
Section 2 - Installation
25
Unpacking and Inspection
25
Terminations, Controls and Indicators
25
BOP 5-20DL, Terminations and Controls, Front Panel
25
BOP Rear Panel Terminations and Controls
26
A-C Input Requirements
27
Cooling
27
Preliminary Checkout
28
Installation of Full-Rack BOP Models
30
Slide Installation
30
Load Connection
31
Load Connection, Local Sensing
31
Load Connection, Remote Sensing
32
A-C Ground
32
D-C Ground
32
Load Connection Using Local Sensing at Rear Panel
33
Load Connection Using Local Sensing at Front Panel
33
Load Connection Using Remote Sensing at Rear Panel
34
Load Connection Using Remote Sensing at Front Panel
34
Section 3 - Operation
35
Introduction
35
Power Supply Basics
35
Rear Programming Connector Terminals
36
External Programming Resistors
37
Active Programming Sources
37
External Leads
37
External Voltage Monitor
37
External Current Monitor
38
Local (Front Panel) Output Control
38
Voltage Mode Operation with Current Limiting
38
BOP Voltage Control Channel (Local Control, Local Sensing)
38
Local Control of Current Limiting
40
Current Mode Operation with Voltage Limiting
40
BOP (±) Current Limiting Circuit (Local Control, Local Sensing)
40
BOP Current Control Channel (Local Control, Local Sensing)
41
Local Control of Voltage Limiting
42
BOP (±) Voltage Limiting Circuit (Local Control, Local Sensing)
42
Remote Control of Voltage Channel
43
Remote Voltage Control Using Resistance (Potentiometer)
43
Remote Potentiometer Control of D-C Output Voltage
43
Remote Voltage Control Using Resistance (Decade Box)
44
Remote D-C Output Voltage Control Using Two-Terminal Resistance (Decade)
44
Remote Voltage Control Using D-C Signal Voltage
45
Digital Control of the D-C Output Voltage
45
Using the BOP as a Voltage Amplifier
46
D-C Output Voltage Control with Non-Inverting Configuration and High Impedance ±1V Signal Source
46
Graphs of Possible Input/Output Waveshapes
47
Basic Programming Circuit for Use of BOP as Bipolar Amplifier (Voltage Mode)
47
Remote Control of Current Limiting
48
Programming Circuit for Driving Output Voltage with
48
Remote Control of Current Control Channel
49
Symmetrical Remote Control of the Current Limits
49
Independent Remote Control of + I O and - I O Limits
49
Remote Current Control Using Resistance (Potentiometer)
50
Remote Current Control Using Resistance (Decade Box)
50
Remote Potentiometer Control of the BOP Output Current
50
Remote D-C Output Current Control Using Two-Terminal Resistance (Decade)
50
Remote Current Control Using D-C Signal Voltage
51
And High Impedance (±)1 Volt Signal Source
51
Using the BOP as a Current Amplifier
52
Basic Programming Circuit for BOP as Bipolar Current-Stabilized Amplifier
52
Programming Circuit for Driving Output Current with Bipolar Signal Less than ±10V
52
Remote Control of Voltage Limiting
53
Programming Circuit for Driving Output Current Witha High Impedance Source
53
Symmetrical Remote Control of Voltage Limit
53
Series and Parallel Connection of BOP Power Supplies
54
Independent Remote Control of +E O and -E O Voltage Limit
54
Series Connection, Master/Slave Operation
55
Series Connection (Master/Slave) of Two BOP Power Supplies, with Remote Error Sensing at the Common Load
55
Circuit Breaker Control Circuit
56
Parallel Connection, Master/Slave Operation
57
Circuit Breaker Control Circuit, Simplified Diagram
57
Parallel Connection (Master/Slave) of Two BOP Power Supplies with Remote Error Sensing at the Common Load
59
Alternative Parallel Connection (Master/Slave) for Greater Precision and Stability of Two or more BOP Power Supplies
60
Indicator and Flag Logic Circuit
61
Indicator Light and Flag Logic
61
Digital Control of BOP Power Supplies
62
Simplified Schematic Diagram, BOP 5-20DL
63
Section 4 - Internal Adjustments and Calibration
65
General
65
Equipment Required
65
Adjustment of (±) 10 Volt Calibration Controls (A1R31, A1R32)
66
Uncommitted Amplifier "A" Zero Adjustment (A1R41)
67
Uncommitted Amplifier "B" Zero Adjustment (A1R42)
67
Adjustment of Ammeter Zero Control (A1R50)
67
Adjustment of I O -OFF Zero (A1A1R13) and E O -OFF Zero (A1A1R16)
68
Voltage Channel Zero Adjustment (A1R81)
68
Current Channel Zero Adjustment (A1R83)
69
Calibration of I Ofull Scale Output Current (A3R316) and Front Panel Ammeter (A7Ar3B)
69
Cover Removal and Internal Component Locations, BOP 5-20DL
70
Advertisement
Advertisement
Related Products
KEPCO BOP 50-20GL
KEPCO BOP 50-20MG
KEPCO BOP 50-4
KEPCO BOP 50-8
KEPCO BOP 50-2
KEPCO BOP 50-40MG
KEPCO BOP 50-40ME
KEPCO BOP 50-20ME
KEPCO BOP 500DM
KEPCO BOP 50-20G
KEPCO Categories
Power Supply
Adapter
Cables and connectors
Battery Charger
Recording Equipment
More KEPCO Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL