Procedure 1
Message Check
When the power is turned on, the system performs the Initial Reliability Test (IRT) installed in
the BIOS ROM. The IRT tests each IC on the system board and initializes it.
If an error message displays, perform Check 1.
If there is no error message, go to Procedure 2.
If the Toshiba MS-DOS is properly loaded, go to Procedure 3.
Check 1
If one of the following error messages displays on the screen, press the F1 key as
the message instructs.
(a)
*** Error in CMOS.
Check system.
(b)
*** Error in CMOS.
Check system.
(c)
*** Error in CMOS.
Check system.
(d)
*** Error in CMOS.
Check system.
(e)
*** Error in CMOS.
Check system.
These errors occur when the system configuration preserved in the RTC memory
(CMOS-type memory) is not the same as the actual configuration or when the data
is lost.
If you press the F1 key as the message instructs, the system configuration in the
RTC memory configuration is set to the default setting. If error message (b)
appears often when power is turned on, replace the RTC battery. If any other
error message displays, perform Check 2.
Check 2
If the following error message displays on the screen, press any key as the message
instructs.
WARNING:
PRESS ANY KEY TO CONTINUE.
This message appears when data stored in RAM under the resume function is lost
because the battery has become discharged or the system board is damaged. Go
to Procedure 3.
If any other message appears, perform Check 3.
T1960CS/T1960CT
Bad HDD type ***
Then press [F1] key ......
Bad battery ***
Then press [F1] key ......
Bad check sum ***
Then press [F1] key ......
Bad memory size ***
Then press [F1] key ......
Bad time function ***
Then press [F1] key ......
RESUME FAILURE.
2-9