Minimum startup configuration

Field Replaceable Units (FRU)
If the server does not start up or other problems occur, it may be necessary to
take the system down to its most basic configuration in order to isolate the
defective component.
The minimum startup configuration consists of the following components and
cables:
Component
System board
1 CPU with CPU heat sink
1 memory module
Front panel module
1 Power supply module
Table 7: Minimum startup configuration - components
Cable
Front panel cable
Power cable
Table 8: Minimum startup configuration - cables
Ê Shut down the server as described in section
page
62.
Ê Remove the AC power cords from the PSU cable brackets and disconnect
them from the system as described in section
from the mains" on page
790
Notes and reference
no TPM, UFM or expansion cards installed
installed in socket CPU 1, see section
"Installing processors" on page 486
installed in DIMM slot 1A, see section
"Memory sequence" on page 468
without connected front LAN module
installed in PSU slot 1, see section
PSU modules" on page 166
Notes and reference
see section
module" on page 601
see section
on page 175
63.
Upgrade and Maintenance Manual
"Replacing the front panel
"Replacing the power backplane"
"Shutting down the server" on
"Disconnecting the server
TX300 S8 / RX350 S8
"Installing