Verifying System Information Backup / Restore - Fujitsu PRIMERGY TX300 S8 Upgrade And Maintenance Manual

Table of Contents

Advertisement

Basic software procedures
Ê Press the Power On / Off button. The system starts the POST process.
I
In iRMC recovery mode, the "FUJITSU" logo does not show up.
The system will detect the USB stick.
I
If the BIOS cannot identify the USB stick, the pop-up message
Failed to boot for Emergency flash. Please Reset now.
will show up in the center of the screen.
Ê Choose the Recovery_L option from the update tool menu to start the iRMC
update process.
V
CAUTION!
Do not interrupt the iRMC upgrade process after it has started. If the
process is interrupted, the iRMC BIOS may be permanently
corrupted.
I
If the iRMC does not work after flashing, disconnect the system from
the mains and reconnect it again.
Ê Shut down the server by pressing the power On / Off button.
Ê Disconnect the server from the mains to exit the iRMC recovery state.
5.2.2

Verifying system information backup / restore

To avoid the loss of non-default settings when replacing the system board, a
backup copy of important system configuration data is automatically stored from
the system board NVRAM to the Chassis ID EPROM. After replacing the
system board the backup data is restored from the Chassis ID board to the new
system board.
In order to verify whether the backup or restore process has been successful,
check the System Event Log (SEL) using the ServerView Operations Manager
(see also section
page
149).
136
"Viewing and clearing the System Event Log (SEL)" on
Upgrade and Maintenance Manual
TX300 S8 / RX350 S8