Installing The Slimline Odd - Fujitsu PRIMERGY TX300 S8 Upgrade And Maintenance Manual

Table of Contents

Advertisement

Accessible drives
12.7
Slimline ODD in 4x 3.5-inch HDD extension
box

12.7.1 Installing the slimline ODD

Upgrade and Repair Unit
(URU)
Tools: – Phillips PH2 / (+) No. 2 screw driver
– Slotted screw driver (for bending in or out accessible drive
mounting brackets)
12.7.1.1 Preliminary steps
"Shutting down the server" on page 62
Ê
"Disconnecting the server from the mains" on page 63
Ê
Ê When working on a rack-mounted server:
"Extending / removing the server from the rack" on page 64
"Opening the server" on page 68
Ê
I
The front cover only needs to be removed in order to remove
accessible drive dummy covers (see section
drive dummy covers" on page
already installed in the server and will be removed in order to install
a slimline ODD or LSD module, skip this step.
"Removing the system air duct" on page 81
Ê
"Removing the system fan holder" on page 330
Ê
Ê If the HDD extension box is already installed in the server, disconnect all
cables from the HDD backplane and remove the extension box as described
in section
"Removing the 4x 3.5-inch HDD extension box" on page
588
Upgrade and Maintenance Manual
Average task duration:
10 minutes
"Removing accessible
533). If the HDD extension box is
299.
TX300 S8 / RX350 S8

Hide quick links: