Sensors - HP P2000 G3 Cli Reference Manual

Msa system
Hide thumbs Also See for P2000 G3:
Table of Contents

Advertisement

sensors

Properties
Table 70
sensors properties
Name
durable-id
enclosure-id
sensor-name
value
status
status-numeric
sensor-location
sensor-type
466 XML API basetype properties
Type
Description
Sensor ID. For example: temp_controller-ID.sensor-number;
string
voltage_controller-ID.sensor-number, current_enclosure-
ID.sensor-number.
Enclosure ID.
uint32
Sensor name and location.
string
For a sensor, its value.
string
For overall unit status, one of the status values below.
OK: The sensor is present and detects no error condition.
string
Warning: The sensor detected a non-critical error condition. Temperature,
voltage, or current is between the warning and critical thresholds.
Error: The sensor detected a critical error condition. Temperature, voltage,
or current exceeds the critical threshold.
Unavailable: The sensor is present with no known errors, but has not
been turned on or set into operation because it is initializing. This typically
occurs during controller startup.
Unrecoverable: The enclosure management processor (EMP) cannot
communicate with the sensor.
Unknown: The sensor is present but status is not available.
Not Installed: The sensor is not present.
Unsupported: Status detection is not implemented.
Numeric equivalents for status values.
string
0: Unsupported
1: OK
2: Error
3: Warning
4: Unrecoverable
5: Not Installed
6: Unknown
7: Unavailable
Sensor location in a controller enclosure.
uint32
1: Unknown
2: Overall unit status
5: Power supply unit
7: Enclosure
8: On board
2: Overall unit status
uint32
3: Temperature
6: Capacitor charge
9: Voltage

Hide quick links: