Table 31
enclosures properties (continued)
Name
Type
midplane-type
string
midplane-type-
string
numeric
enclosure-power
string
pcie2-capable
string
pcie2-capable-
string
numeric
health
string
health-numeric
string
health-reason
string
health-
string
recommendation
Example
# show enclosures
...
<OBJECT basetype="enclosures" name="enclosures" oid="1" format="rows">
<PROPERTY name="durable-id" type="string">enclosure_1</PROPERTY>
<PROPERTY name="enclosure-id" type="uint8">1</PROPERTY>
<PROPERTY name="enclosure-wwn" type="string">500c0ff0daa4943c</PROPERTY>
<PROPERTY name="name" type="string"></PROPERTY>
<PROPERTY name="location" type="string"></PROPERTY>
<PROPERTY name="rack-number" type="uint8">0</PROPERTY>
<PROPERTY name="rack-position" type="uint8">0</PROPERTY>
Description
Enclosure midplane type.
•
2U24-6Gv2: Midplane for 2U, reduced-depth, 24-disk enclosure with
6-Gbps maximum data rate to disks
•
2U24-6G: Midplane for 2U, 24-disk enclosure with 6-Gbps maximum data
rate to disks
•
2U24-3G: Midplane for 2U, 24-disk enclosure with 3-Gbps maximum data
rate to disks
•
2U12-6Gv2: Midplane for 2U, reduced-depth, 12-disk enclosure with
6-Gbps maximum data rate to disks
•
2U12-6G: Midplane for 2U, 12-disk enclosure with 6-Gbps maximum data
rate to disks
•
2U12-3G: Midplane for 2U, 12-disk enclosure with 3-Gbps maximum data
rate to disks
•
N/A: Other type of midplane
Numeric equivalents for midplane-type values.
•
0: 2U12-3G
•
1: 2U24-3G
•
2: 2U12-6G
•
3: 2U24-6G
•
5, 9, 13: 2U24-6Gv2
•
6, 10: 2U12-6Gv2
Enclosure power in watts.
False: Enclosure is not capable of using PCI Express version 2.
•
Numeric equivalents for pcie2-capable values.
•
0: False
•
1: True
•
OK
•
Degraded
•
Fault
•
Unknown
Numeric equivalents for health values.
•
0: OK
•
1: Degraded
•
2: Fault
•
3: Unknown
If Health is not OK, the reason for the health state.
If Health is not OK, the recommended actions to take to resolve the health issue.