HP P2000 G3 Cli Reference Manual page 192

Msa system
Hide thumbs Also See for P2000 G3:
Table of Contents

Advertisement

Sync Cache Mode
Shows how the SCSI SYNCHRONIZE CACHE command is handled:
Immediate: Good status is returned immediately and cache content is unchanged.
Flush To Disk: Good status is returned only after all write-back data for the specified volume
is flushed to disk.
Independent Cache Performance Mode
Not supported. Disabled by default.
Missing LUN Response
Shows whether host drivers may probe for LUNs until the host drivers reach the LUN to which they
have access.
Not Ready: Sends a reply that there is a LUN where a gap has been created but that it's "not
ready." Sense data returned is sensekey = 2, code = 4, qualifier = 3. This is the default.
Illegal Request: Sends a reply that there is a LUN but that the request is "illegal." Sense
data returned is sensekey = 5, code = 25h, qualifier = 0.
Controller Failure
Shows whether the cache policy will change from write-back to write-through when a controller fails.
Disabled: The controller failure trigger is disabled. This is the default.
Enabled: The controller failure trigger is enabled.
Supercap Failure
Shows whether the cache policy will change from write-back to write-through when the
super-capacitor that provides backup power for cache is not fully charged or fails.
Disabled: The super-capacitor failure trigger is disabled.
Enabled: The super-capacitor failure trigger is enabled. This is the default.
CompactFlash Failure
Shows whether the cache policy will change from write-back to write-through when CompactFlash
memory is not detected during POST (Power-On Self-Test), fails during POST, or fails during controller
operation.
Disabled: The CompactFlash failure trigger is disabled.
Enabled: The CompactFlash failure trigger is enabled. This is the default.
Power Supply Failure
Shows whether the cache policy will change from write-back to write-through when a power supply
fails.
Disabled: The power-supply failure trigger is disabled. This is the default.
Enabled: The power-supply failure trigger is enabled.
Fan Failure
Shows whether the cache policy will change from write-back to write-through when a fan fails.
Disabled: The fan failure trigger is disabled. This is the default.
Enabled: The fan failure trigger is enabled.
Temperature Exceeded
Shows whether the system will shut down a controller when its temperature exceeds the critical
operating range.
Disabled: The over-temperature failure trigger is disabled. This is the default.
Enabled: The over-temperature failure trigger is enabled.
192 Alphabetical list of commands

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents