redundancy
Properties
Table 54
redundancy properties
Name
redundancy-mode
redundancy-
mode-numeric
redundancy-
status
redundancy-
status-numeric
controller-a-
status
controller-a-
status-numeric
controller-a-
serial-number
controller-b-
status
controller-b-
status-numeric
controller-b-
serial-number
440 XML API basetype properties
Type
Description
The system's operating mode, also called the cache redundancy mode.
string
•
Active-Active ULP: Both controllers are active using ULP (Unified LUN
Presentation). Data for volumes configured to use write-back cache is
automatically mirrored between the two controllers to provide fault
tolerance.
•
Single Controller: The enclosure contains a single controller.
•
Fail Over: Operation has failed over to one controller because its partner
is not operational. The system has lost redundancy.
•
Down: Both controllers are not operational.
Numeric equivalents for redundancy-mode values.
string
•
2: Active-Active ULP
•
3: Single Controller
•
4: Fail Over
•
5: Down
•
Redundant: Both controllers are operational.
string
•
Operational but not redundant: In active-active mode, one
controller is operational and the other is offline. In single-controller mode,
the controller is operational.
•
Down: This controller is not operational.
•
Unknown: Status information is not available.
Numeric equivalents for redundancy-status values.
string
•
1: Redundant
•
3: Operational but not redundant
•
4: Down
•
5: Unknown
•
Operational: The controller is operational.
string
•
Down: The controller is installed but not operational.
•
Not Installed: The controller is not installed.
Numeric equivalents for controller-a-status values.
string
•
0: Operational
•
1: Down
•
2: Not Installed
•
Controller module serial number
string
•
Not Available: The controller is down or not installed.
•
Operational: The controller is operational.
string
•
Down: The controller is installed but not operational.
•
Not Installed: The controller is not installed.
Numeric equivalents for controller-b-status values.
string
•
0: Operational
•
1: Down
•
2: Not Installed
Controller module serial number
•
string
•
Not Available: The controller is down or not installed.