HP P2000 G3 Cli Reference Manual page 135

Msa system
Hide thumbs Also See for P2000 G3:
Table of Contents

Advertisement

partner-firmware-upgrade enabled|disabled|on|off
Optional. Sets whether component firmware versions are monitored and will be automatically
updated on the partner controller.
disabled or off: Partner firmware upgrade is disabled.
enabled or on: Partner firmware upgrade is enabled. This is the default.
partner-notify enabled|disabled|on|off
Optional. Sets whether to notify the partner controller that a trigger condition occurred. Enable this
option to have the partner also change to write-through mode for better data protection. Disable this
option to allow the partner continue using its current caching mode for better performance. The
default is disabled.
disabled or off: Notification is disabled. This is the default.
enabled or on: Notification is enabled.
power-supply-failure enabled|disabled|on|off
Optional. Sets whether the cache policy automatically changes to write-through when a power
supply fails.
disabled or off: The power-supply failure trigger is disabled. This is the default.
enabled or on: The power-supply failure trigger is enabled.
smart enabled|disabled|on|off|detect-only
Optional. Enables or disables SMART (Self-Monitoring Analysis and Reporting Technology)
monitoring for all disks in the storage system.
disabled or off: Disables SMART for all disks in the system and for all disks added to the
system.
enabled or on: Enables SMART for all disks in the system and for all disks added to the system.
This is the default.
detect-only: Detects but does not change the SMART setting of each disk in the system, and
for each new disk added to the system.
super-cap-failure enabled|disabled|on|off
Optional. Sets whether the cache policy will change from write-back to write-through when the
super-capacitor that provides backup power for cache is not fully charged or fails.
disabled or off: The super-capacitor failure trigger is disabled.
enabled or on: The super-capacitor failure trigger is enabled. This is the default.
sync-cache-mode immediate|flush
Optional. Sets how the SCSI SYNCHRONIZE CACHE command is handled.
immediate: Good status is returned immediately and cache content is unchanged. This option
is the default.
flush: Good status is returned only after all write-back data for the specified volume is flushed
to disk.
temperature-exceeded enabled|disabled|on|off
Optional. Sets whether the system will shut down a controller when its temperature exceeds the
critical operating range.
disabled or off: The over-temperature trigger is disabled. This is the default.
enabled or on: The over-temperature trigger is enabled.
HP P2000 G3 MSA System CLI Reference Guide 135

Hide quick links:

Advertisement

Table of Contents
loading