Sam4s SPS-300 Programming & Operation Manual page 189

Hide thumbs Also See for SPS-300:
Table of Contents

Advertisement

Page Field
12
RESET GST AFTER
SERVICE ON HARD CHECK
ROUNDING ON SUBTOTAL
ROUNDING ON CASH
13
PRICE LEVEL IS
0:POP UP AFTER ITEM
1:POP UP AFTER SALE
2:STAYDOWN
ELECTRONIC JOURNAL
14
PROMPT OPERATOR
WHEN EJ BUFFER IS FULL
STOP OPERATIONS WHEN
EJ BUFFER IS FULL
SEND ONLY NEGATIVE
ENTRIES TO EJ
X REPORT AND
DECLARATION SEND TO
EJ
15
SEND RESET REPORT TO
EJ
DIRECT MULTIPLICATION
MORE THAN ONE DIGIT
TENDER VALIDATION
Y:AMT TENDERED
N:AMT OF SALE
16
ROUNDING SYSTEM
Rounding Rates
SAM4S SPS-300 Series Electronic Cash Register AU
Value
Description
Y or N
Select Y to enable resetting GST on the Hard Check just
serviced to avoid GST amount been incorrectly cumulated.
Y or N
WARNING: By law, the rounding is only apply to CASH
transaction. Please check with authority before changing this
option.
Select Y to execute rounding when SUBTOTAL is pressed.
The "ROUNDING ON CASH" has to set to N.
Y or N
WARNING: By law, the rounding is only apply to CASH
transaction. Please check with authority before changing this
option.
Select Y to execute rounding when CASH is pressed. The
"ROUNDING ON SUBTOTAL" has to set to N.
If you press a price level key, you have the option of the
0
level key applying only to the next item (0), having the same
level key apply to any subsequent item registered in the same
transaction (1), or having the same level key apply to any
subsequent item on any subsequent transaction(2).
Y or N
Select Y to enable the electronic journal. The electronic
journal captures in memory what you would print line by line
on a traditional journal. The four options that follow control
the electronic journal feature. The electronic journal can be
read and printed in the X control lock position or reset and
printed in the Z control lock position.
Y or N
If the electronic journal is enabled above, select Y if you
wish to display a message to notify the operator when the
journal memory is full.
Y or N
If the electronic journal is enabled above, select Y if you
wish to stop operations when the journal memory is full.
Y or N
If the electronic journal is enabled above, select Y if you
wish to capture only transactions with negative entries.
Y or N
If the electronic journal is enabled above, select Y if you
wish to capture X report and declaration.
Y or N
If the electronic journal is enabled above, select Y if you
wish to capture reset reports.
If you allow direct multiplication of a preset PLU, you can
Y or N
allow only single digit multiplication or multiplication by
more than one digit.
Y or N
Validation is allowed if an appropriate optional printer is
connected to an RS-232C port. Here you can choose the
content of single line validation
Y or N
Select Y to enable Rounding System.
Enter the high amount of the first range where you are
prompted. The low amount of the next range will be
computed automatically.
Program Mode Programming • 177