Stairmaster FreeRunner 5400 ESS Owner's Manual page 46

Hide thumbs Also See for FreeRunner 5400 ESS:
Table of Contents

Advertisement

12.
Perform the following Positive Output to Field test on the
• Turn the power off.
• Disengage the
brake.
• Remove the white wire from the B+ terminal on the alternator.
• Remove the brown wire from the field (FLO) terminal on the
alternator.
• Place alligator clips on the
alternator.
• Step on the machine for 15 - 20 seconds.
• If res istance is ach ieved during this
correct current
flow.
• If no resistance builds up during this
alternator or bad alternator
13. Unplug the diode from the FLO terminal of the
14.
Use a multimeter set to ohms to test the diode. A good diode will show a
high resistance reading in one direction and a low resistance reading when
the multimeter leads are reversed
15.
Unplug the load resistor from the power control board. Set your multimeter
to
ohms.
Insert the multimeter leads into the load resistor plug.
16.
A load resistor in proper working condition should read approximately 0.5
ohms.
If the number recorded is outside the specified range, replace the
load
resistor.
17.
Check the ma in cable assemblies for continuity, and cross check each wire
in the cables for shorted wires (see Figure 35).
18.
Contact our Customer Service Department at (800) 331-3578 for assistance.
International customers should contact their local
TROUBLESHOOTING
alternator:
B+
terminal and the field terminal of the
time,
your
alternator
time,
you either have a bad
brushes.
alternator.
.
distributors.
has
Page 33