Acl Flow Meter - D-Link Xstack DES-3528 Series Reference Manual

Stackable fast ethernet switch web ui
Hide thumbs Also See for Xstack DES-3528 Series:
Table of Contents

Advertisement

xStack® DES-3528/DES-3552 Series Layer 2 Managed Stackable Fast Ethernet Switch Web UI Reference Guide

ACL Flow Meter

This page is used to configure the flow-based metering function. The metering function supports three modes:
single rate two color, single rate three color, and two rate three color. The access rule must be created before the
parameters of this function can be applied.
For the single rate two color mode, users may set the preferred bandwidth for this rule, in Kbps and once the
bandwidth has been exceeded, overflow packets will be dropped or be remarked to other DSCP, depending on the
user configuration.
For single rate three color mode, users need to specify the committed rate in Kbps, the committed burst size and
the excess burst size.
For the two rate three color mode, users need to specify the committed rate in Kbps, the committed burst size, the
peak rate and the peak burst size.
The green color packet will be treated as the conforming action, the yellow color packet will be treated as the
exceeding action, and the red color packet will be treated as the violating action.
Users may also choose to count conformed, exceeded and violated packets by selecting Enabled from the Counter
drop-down menu. If the counter is enabled, the counter setting in the access profile will be enabled. Users may only
enable two counters for one flow meter at any given time.
To view this window, click ACL > ACL Flow Meter, as shown below:
The fields that can be configured or Viewed are described below:
Parameter
Profile ID
Profile Name
Access ID (1-128)
Click the Find button to locate a specific entry based on the information entered.
Click the Add button to add a new entry based on the information entered.
Click the View All button to display all the existing entries.
Click the Delete All button to remove all the entries listed.
Click the Modify button to re-configure the specific entry.
Click the View button to display the information of the specific entry.
Click the Delete button to remove the specific entry.
After clicking the Add or Modify button, the following page will appear:
Figure 7-45 ACL Flow Meter window
Description
Enter the Profile ID for the flow meter.
Enter the Profile Name for the flow meter.
Enter the Access ID for the flow meter.
210

Advertisement

Table of Contents
loading

This manual is also suitable for:

Xstack des-3552 series

Table of Contents