Kyocera KM-1650 Service Manual page 78

Hide thumbs Also See for KM-1650:
Table of Contents

Advertisement

Maintenance
item No.
Initializing backup memory
U022
Description
Initializes only the data set for the optical section or initializes various setting data when installing the optional
network scanner board.
Purpose
To be executed after replacing the scanner unit or installing the network scanner board.
Method
1. Press the start key. The screen for executing is displayed.
2. Select the EXECUTE using the up/down cursor keys. It is displayed in reverse.
3. Press the start key. The data for the optical section (U060 to 067, U092 to 099, U403, U990 and U991)
is initialized.
The setting data of scanner function initial settings are initialized, and the registered transmission and
reception are cleared.
Completion
Press the stop/clear key. The screen for selecting a maintenance item No. is displayed.
Evacuation of backup data
U026
Description
Transfers the backup data of the main PCB to the EEPROM.
Purpose
Used when replacing the main PCB.
Method
1. Press the start key. The screen for executing is displayed.
2. Select the EXECUTE using the up/down cursor keys. It is displayed in reverse.
3. Press the start key to transfer the backup data. The screen displays the result.
EXECUTE
CHECK SUM: ****
CODE : XXXX (See the table below)
Code
0000
0101
0102
4. Press the stop/clear key. The screen for selecting a maintenance item No. is displayed.
Completion
Press the stop/clear key. The screen for selecting a maintenance item No. is displayed.
Description
Description
Processing ends correctly.
Verification abnormality occurs.
Verification abnormality occurs at the time of check sum entry.
2DA/2DB
1-4-9