Code
C6000
Broken fixing heater wire
In fixing warm-up, the time to reach
°
°
50
C/122
F exceeds 13.5 s, the time to
°
reach 100
C/212
time to reach the primary stabilization
exceeds 10 s or the time to reach the
secondary stabilization exceeds 24 s.
C6020
Abnormally high fixing unit ther-
mistor temperature
The fixing temperature exceeds 230
°
446
F for 40 ms.
C6050
Abnormally low fixing unit thermistor
temperature
The fixing temperature remains below
°
°
90
C/194
F for 1 s.
C6400
Zero-crossing signal problem
The engine PCB does not detect the
zero-crossing signal for the time speci-
fied below. At power-on: 3 s Others: 5 s
C7800
Broken external temperature ther-
mistor
The input voltage is 0.5 V or less.
Contents
°
F exceeds 10 s, the
°
C/
Causes
Check procedures/corrective measures
Fixing heater M or
Check and reinstall if necessary.
S installed incor-
rectly.
Broken fixing
Check for continuity. If none, replace the fix-
heater M or S wire.
ing heater M or S.
Shorted thermistor. Measure the resistance. If it is 0 Ω, replace
the thermistor.
Broken heater con-
Replace the power supply PCB and check
trol circuit on the
for correct operation.
power supply PCB.
Poor contact in the
Reinsert the connector. Also check for conti-
thermistor connec-
nuity within the connector cable. If none,
tor terminals.
remedy or replace the cable.
Measure the resistance. If it is ∞ Ω, replace
Broken fixing ther-
mistor wire.
the fixing thermistor.
Fixing thermistor
Check and reinstall if necessary.
installed incor-
rectly.
Fixing thermostat
Check for continuity. If none, replace the fix-
triggered.
ing thermostat.
Fixing heater M or
Check and reinstall if necessary.
S installed incor-
rectly.
Broken fixing
Check for continuity. If none, replace the fix-
heater M or S wire.
ing heater M or S.
Poor contact in the
Reinsert the connector. Also check for conti-
connector termi-
nuity within the connector cable. If none,
nals.
remedy or replace the cable.
Defective power
Check if the zero-crossing signal is output
supply PCB.
from YC2-5 on the power supply PCB. If not,
replace the power supply PCB.
Defective engine
Replace the engine PCB if C6400 is
PCB.
detected while YC2-5 on the power supply
PCB outputs the zero-crossing signal.
Poor contact in the
Reinsert the connector. Also check for conti-
humidity sensor
nuity within the connector cable. If none,
connector termi-
remedy or replace the cable.
nals.
Defective humidity
Replace the drawer PCB and check for cor-
sensor.
rect operation.
Remarks