2DA/2DB
Code
C3300
Optical system (AGC) problem
After AGC, correct input is not obtained
at CCD.
C4000
Polygon motor synchronization prob-
lem
The polygon motor does not reach the
stable speed within 15 s of the START
signal turning on.
C4010
Polygon motor steady-state problem
The polygon motor rotation is not stable
for 5 s after the polygon motor rotation
has been stabilized.
C4200
BD steady-state problem
The MIP detects a BD error for 600 ms
after the polygon motor rotation has
been stabilized.
C6000
Broken fixing heater wire
In fixing warm-up, the time to reach
°
°
50
C/122
F exceeds 13.5 s, the time to
°
reach 100
C/212
time to reach the primary stabilization
exceeds 10 s or the time to reach the
secondary stabilization exceeds 24 s.
1-5-22
Contents
°
F exceeds 10 s, the
Causes
Check procedures/corrective measures
Insufficient expo-
Replace the exposure lamp or inverter PCB.
sure lamp luminos-
ity.
Defective engine
Replace the engine PCB and check for cor-
PCB.
rect operation.
Incorrect shading
Adjust the position of the contact glass
position.
(shading plate). If the problem still occurs,
replace the scanner home position switch.
Defective CCD
Replace the ISU.
PCB.
Poor contact in the
Reinsert the connector. Also check for conti-
polygon motor con-
nuity within the connector cable. If none,
nector terminals.
remedy or replace the cable.
Defective polygon
Replace the LSU.
motor.
Defective engine
Replace the engine PCB and check for cor-
PCB.
rect operation.
Poor contact in the
Reinsert the connector. Also check for conti-
polygon motor con-
nuity within the connector cable. If none,
nector terminals.
remedy or replace the cable.
Defective polygon
Replace the LSU.
motor.
Defective engine
Replace the engine PCB and check for cor-
PCB.
rect operation.
Defective laser
Replace the LSU.
diode.
Defective polygon
Replace the LSU.
motor.
Defective main
Replace the main PCB and check for correct
PCB.
operation.
Defective engine
Replace the engine PCB and check for cor-
PCB.
rect operation.
Poor contact in the
Reinsert the connector. Also check for conti-
thermistor connec-
nuity within the connector cable. If none,
tor terminals.
remedy or replace the cable.
Fixing thermistor
Check and reinstall if necessary.
installed incor-
rectly.
Fixing thermostat
Check for continuity. If none, replace the fix-
triggered.
ing thermostat.
Remarks