Self Diagnostic Codes - Kyocera KM-1650 Service Manual

Hide thumbs Also See for KM-1650:
Table of Contents

Advertisement

2DA/2DB-3.0

(2) Self diagnostic codes

Code
C0030
Fax control PCB*
Processing with the fax software was
disabled due to a hardware or software
problem.
C0070
Fax control PCB*
detection problem
Fax software is not compatible with main
software.
C0100
Backup memory read/write problem
(main PCB flash)
Read and write data does not match.
C0110
Backup memory data problem (main
PCB flash)
Data in the specified area of the backup
memory does not match the specified
values.
C0130
Backup memory read/write problem
(main PCB EEPROM)
Read and write data does not match.
C0140
Backup memory data problem (main
PCB EEPROM)
Data in the specified area of thebackup
memory does not match the specified
values.
C0150
Backup memory read/write problem
(engine PCB)
Read and write data does not match.
C0160
Backup memory data problem (engine
PCB)
Data in the specified area of the backup
memory does not match the specified
values.
C0170
Accounting count problem
When the power is turned on, the total
count and the scan count are abnormal
both on the main PCB and the engine
PCB.
C0180
Machine number mismatch
When the power is turned on, the
machine number does not match
between the main PCB and the engine
PCB.
*1: Optional. *2: Optional for 16 ppm model. Standard for 20 ppm model.
1-5-18
Contents
1
system problem
1
incompatibility
Causes
Check procedures/corrective measures
Defective fax con-
Replace the fax control PCB and check for
trol PCB.
correct operation.
Fax software or
Check the version of the Fax software and
main software is
the main software, upgrade the version to
something of the
the compatible software.
other machine.
Defective main
Replace the main PCB and check for correct
PCB.
operation.
Problem with the
Turn safety switch off and back on and run
backup memory
maintenance item U020 to set the contents
data.
of the backup memory data again.
Defective backup
If the C0110 is displayed after re-setting the
RAM.
backup memory contents, replace the main
PCB.
Defective
Replace the main PCB and check for correct
EEPROM or main
operation.
PCB.
Problem with the
Turn safety switch off and back on and run
backup memory
maintenance item U020 to set the contents
data.
of the backup memory data again.
Defective
If the C0140 is displayed after re-setting the
EEPROM.
backup memory contents, replace the
EEPROM or main PCB.
Defective engine
Replace the engine PCB and check for cor-
PCB.
rect operation.
Problem with the
Turn safety switch off and back on and run
backup memory
maintenance item U020 to set the contents
data.
of the backup memory data again.
Defective backup
If the C0160 is displayed after re-setting the
RAM.
backup memory contents, replace the
engine PCB.
Defective main
Replace the main PCB or engine PCB and
PCB or engine
check for correct operation.
PCB.
Correct EEPROM
Install the correct EEPROM. If it does not
is not installed.
solve the problem, contact the Service
Administrative Division.
Data damage of
Contact the Service Administrative Division.
EEPROM.
Remarks

Hide quick links:

Advertisement

Table of Contents
loading