1-3-7

Installing the key counter (option)

Key counter installation requires the following parts:
Key counter cover (P/N 2A360010)
Key counter retainer (P/N 66060030)
Key counter mount (P/N 66060040)
Key counter assembly (P/N 41529210)
Four (4) M4 x 6 bronze TP-A screws (P/N B4304060)
One (1) M4 x 35 round head screw (P/N B0004350)
Two (2) M3 x 6 bronze flat-head screws (P/N B2303060)
One (1) M3 bronze nut (P/N C2303000)
Key counter mounting plate (P/N 2C960100)
Key counter wire (P/N 2C960110)
Procedure
1. Fit the key counter socket assembly to the
key counter retainer using the two screws
and nut.
2. Fit the key counter mount to the key counter
cover using the two screws, and attach the
key counter retainer to the mount using the
two screws.
M4 x 6 screws (B4304060)
Key counter retainer (66060030)
M3 nut
(C2303000)
M4 x 6 screws (B4304060)
Key counter socket assembly
(41529210)
M3 x 6 flat-head screws (B2303060)
Key counter mount (66060040)
Key counter cover
(2A360010)
Figure 1-3-31