Attach the transfer unit.
9. Insert the transfer unit from the MFP front
side and slide it to the left to install to the
ejection part.
10. Place the transfer unit closer to the ejection
side and then secure the front side using the
TP bind screw M3 x 06 and the rear side
using the pin.
TP bind screw
M3 x 06
Release the lever securing fitting.
11. Loosen the screw located at the rear side of
the transfer unit and release the lever secur-
ing fitting in the direction of an arrow, and
then retighten the screw.
Transfer unit
Figure 1-3-43
Lever
securing fitting
Screw
Figure 1-3-44
2DA/2DB
Pin