2DA/2DB-3.0
Load paper.
1. Load paper in the drawer.
Output an own-status report (maintenance item U000).
1. Enter "000" using the numeric keys and
press the start key.
2. Select "MAINTENANCE" and press the start
key to output a list of the current settings of
the maintenance items.
3. Press the stop/clear key.
Exit maintenance mode.
1. Enter "001" using the numeric keys and press the start key.
The machine exits the maintenance mode.
Make test copies.
1. Place an original and make test copies.
End of installation.
1-3-2

Setting initial copy modes

Factory settings are as follows:
Maintenance
item No.
U253
Switching between double and single counts
U254
Turning auto start function on/off
U258
Switching copy operation at toner empty detection
U260
Changing the copy count timing
U264
Setting the display order of the date
U277
Setting auto aplication change time
U326
Setting the black line cleaning indication
U342
Setting the ejection restriction
U343
Switching between duplex/simplex copy mode
U344
Setting preheat/energy saver mode
1-3-6
Contents
Factory setting
Double count
ON
SINGLE MODE
After ejection
Month/Day/Year (Inch specifications)
Day/Month/Year (Metric specifications)
30
ON
ON
OFF
ENERGY STAR