Section
Jam code
Feedshift
52
section
53
54
55
56
57
Duplex
60
section
61
*1: Optional. *2: Optional for 16 ppm model. Standard for 20 ppm model.
Description
Misfeed in the feedshift
section (paper feed from
bypass tray)
Misfeed in the feedshift
section (paper feed from
drawer)
Misfeed in the feedshift
section (paper feed from
2
first paper feeder*
)
Misfeed in the feedshift
section (paper feed from
1
second paper feeder*
)
Misfeed in the feedshift
section (paper feed from
1
third paper feeder*
)
Misfeed in the feedshift
section (paper feed from
1
duplex section*
)
Misfeed in duplex paper
1
conveying section*
Misfeed in duplex exit
1
section*
The feedshift switch (FSSW) does not turn on within 6320 ms
of feedshift switch (FSSW) turning on.
The feedshift switch (FSSW) does not turn off within 1530 ms
of paper switchback.
The feedshift switch (FSSW) does not turn on within 1530 ms
of paper switchback.
The feedshift switch (FSSW) does not turn on within 6320 ms
of feedshift switch (FSSW) turning on.
The feedshift switch (FSSW) does not turn off within 1530 ms
of paper switchback.
The feedshift switch (FSSW) does not turn on within 1530 ms
of paper switchback.
The feedshift switch (FSSW) does not turn on within 6320 ms
of feedshift switch (FSSW) turning on.
The feedshift switch (FSSW) does not turn off within 1530 ms
of paper switchback.
The feedshift switch (FSSW) does not turn on within 1530 ms
of paper switchback.
The feedshift switch (FSSW) does not turn on within 6320 ms
of feedshift switch (FSSW) turning on.
The feedshift switch (FSSW) does not turn off within 1530 ms
of paper switchback.
The feedshift switch (FSSW) does not turn on within 1530 ms
of paper switchback.
The feedshift switch (FSSW) does not turn on within 6320 ms
of feedshift switch (FSSW) turning on.
The feedshift switch (FSSW) does not turn off within 1530 ms
of paper switchback.
The feedshift switch (FSSW) does not turn on within 1530 ms
of paper switchback.
The feedshift switch (FSSW) does not turn on within 6320 ms
of feedshift switch (FSSW) turning on.
The feedshift switch (FSSW) does not turn off within 1530 ms
of paper switchback.
The feedshift switch (FSSW) does not turn on within 1530 ms
of paper switchback.
The duplex paper conveying switch (DUPPCSW)*
turn off within 3280 ms of the feedshift switch (FSSW) turning
on.
The duplex paper conveying switch (DUPPCSW)*
turn on within 3280 ms of the feedshift switch (FSSW) turning
on.
The duplex paper conveying switch (DUPPCSW)*
turn off within 3280 ms of the feedshift switch (FSSW) turning
off.
The registration switch (RSW) does not turn on within 1760 ms
of the duplex paper conveying switch (DUPPCSW)*
on.
The registration switch (RSW) does not turn off within 1760 ms
of the duplex paper conveying switch (DUPPCSW)*
off.
Conditions
2DA/2DB
1
does not
1
does not
1
does not
1
turning
1
turning
1-5-5