Kyocera KM-1650 Service Manual page 44

Hide thumbs Also See for KM-1650:
Table of Contents

Advertisement

2DA/2DB
3. Remove the rear cover.
4. Cut out the aperture plate on the right cover
using nippers.
5. Connect the 4-pin connector of the key
counter wire (located at a longer distance
from the tube) to YC13 on the engine PCB,
pass the wire through the two clamps, and
pull the other 4-pin connector out from the
aperture of the right cover.
* Arrange the key counter wire behind the
optical system wire as shown in the illustra-
tion.
6. Fold the 7-pin connector of the key counter
wire back, pass the wire through the clamp
at the upper part of the controller box, and
hang it.
7. Pass the connector of the key counter
through the aperture of the key counter
mounting plate, and engage the projection
of key counter mounting plate with the
square hole of the key counter cover.
1-3-20
Aperture
4-pin connector
7-pin connector
Key counter wire
Figure 1-3-32
4-pin connector
Aperture
Projection
Square hole
Figure 1-3-33
Clamp
YC13
Clamp
4-pin connector
Key counter mounting
plate (2C960100)
Key counter
cover

Hide quick links: