2) Load test
Apply the specified braking torque to starter. The
condition is satisfactory if the current draw and
starter speed are within the specifications.
Load test (Standard):
Voltage / Load
MT vehicles
7.5 V/8.6 N (0.88 kgf, 1.93 lb)
AT vehicles
7.7 V/16.0 N (1.63 kgf, 3.60 lb)
Current / Speed
MT vehicles
300 A/920 rpm or more
AT vehicles
400 A/740 rpm or more
3) Lock test
With the starter stalled, or not rotating, measure the
torque developed and current draw when the volt-
age is adjusted to the specified voltage.
Lock test (Standard):
Voltage / Current
MT vehicles
4 V/650 A or less
AT vehicles
3.5 V/940 A or less
Torque
MT vehicles
14.7 N (1.50 kgf, 3.30 lb) or more
AT vehicles
28.9 N (2.95 kgf, 6.50 lb) or more
STARTER
SC-13
STARTING/CHARGING SYSTEMS