Pump Motor Assy; Cap Assy - Epson Stylus Pro 7600 Service Manual

Color large format inkjet printer
Hide thumbs Also See for Stylus Pro 7600:
Table of Contents

Advertisement

EPSON Stylus Pro 7600/9600

4.6.2 Pump Motor ASSY

1.
Remove the Maintenance ASSY.
2.
Remove the two (M3×8) screws securing the Pump Motor ASSY to the Maintenance
ASSY and remove the Pump Motor ASSY.

4.6.3 Cap ASSY

1.
Remove the Maintenance ASSY.
2.
Disconnect the tube which connect the Valve ASSY to the Cap ASSY.
3.
Remove the two screws securing the Cap ASSY and remove the Cap ASSY from the
Maintenance ASSY.
Check for the points below when removing/mounting the Cap
C A U T I O N
ASSY.
Push the cap part down to the valve part and check that the cap
part rebounds with spring force.
Check that the valve part is not dislocated.
Disassembly & Assembly
(See p.199)
(See p.199)
Disassembly and Assembly of Cleaning Mechanism
Pump Motor ASSY
Figure 4-74. Removing the Pump Motor ASSY
Cap ASSY
Figure 4-75. Removing the Cap ASSY
Revision A
Maintenance ASSY
Screws (M3×8) ×2
Valve ASSY
200