Self-Diagnostic Function; Overview; How To Start Self-Diagnostic Function; Functions Of Keys During Self-Diagnosis - Epson Stylus Pro 7600 Service Manual

Color large format inkjet printer
Hide thumbs Also See for Stylus Pro 7600:
Table of Contents

Advertisement

EPSON Stylus Pro 7600/9600

5.2 Self-diagnostic Function

With this function, all the processing except for some items are
C A U T I O N
executed on the assumption that roll paper is used. Take care,
since even sheets, if loaded, are handled as roll paper.
During execution of this function, detection of remaining
volume in ink cartridges and Maintenance Tank is not
performed. Therefore, when you execute this function for print
head replacement or any other work which requires
consumption or discharge of a large volume of ink, check the
remaining volume in ink cartridges and Maintenance Tank
beforehand. (If you neglect this checking, the capacity of the
Maintenance Tank can be exceeded so that ink may flow out;
never forget to perform this checking.)

5.2.1 Overview

Self-diagnosis is chiefly intended to determine the parameters for mechanism
adjustment and firm adjustment.
This function is incorporated in the printer firmware. It is enabled when the power to
the printer is turned on while pressing the specific panel keys.
NOTE: The printer can not be shifted from the normal mode to the self-
diagnostic mode.

5.2.1.1 How to Start Self-diagnostic Function

The key operation to start the self-diagnostic function is as follows:
1.
Power is off.
Press "Paper Feed ∆" + "Paper Feed ∇" + "Cut / Eject".
2.
3.
Turn the power on.
4.
The self-diagnostic menu is displayed.
5.
Turn the power off to close the self-diagnostic function.
Adjustment

5.2.1.2 Functions of Keys during Self-diagnosis

Described below are the functions of panel keys in the self-diagnostic mode:
Table 5-15. Key Functions in Self-diagnostic Mode
Normal Mode
Pause
SelecType
Paper Source
(Items)
Paper Feed ∆
Paper Feed ∇
Cut / Eject (Enter)
Cleaning
Figure 5-1. Panel Function in Self-diagnostic Mode
Self-diagnostic Function
Self-diagnostic
Mode
Previous Level
Returns the setting item to the previous level of
the menu hierarchy.
Setting Item (Next)
Lowers the level in the menu hierarchy by one.
Setting Item
Enhances the level in the menu hierarchy by one.
(Previous)
Setting Value +
Changes the menu in the upward direction.
Setting value +
Setting Value –
Changes the menu in the downward direction.
Setting value –
Enter
Sets the setting value.
Paper Feed & Cut
If it is pressed, the paper is fed, and when it is
released, the paper is cut.
Moves the cursor. (only for specific items)
Revision A
Functions
220

Hide quick links:

Advertisement

Table of Contents
loading