Cr Encoder Sensor Assy - Epson Stylus Pro 7600 Service Manual

Color large format inkjet printer
Hide thumbs Also See for Stylus Pro 7600:
Table of Contents

Advertisement

EPSON Stylus Pro 7600/9600

4.3.5 CR Encoder Sensor ASSY

1.
Remove the R Side Cover. (p.160)
2.
Remove the L Side Cover. (p.163)
3.
Remove the I/H Cover. (p.164)
4.
Remove the H Top Cover. (p.165)
5. Remove one screw (CPP M3×6), two screws (CP(W): M3×6) and one screw (M3×16)
securing the CR Board Guide, and also the ground line and the toothed washer (M3),
and remove the CR Board
Guide.(See Figure 4-30)
6.
Disconnect the connector (5-pin, white) for the CR Encoder Sensor from the CR
Board.
If you can not disconnect easily the connector for the CR Encoder
C A U T I O N
Sensor, do not disconnect it by undue force. Disconnect the two
FFCs for the print head first and then the connector for the CR
Encoder Sensor.
7.
Remove the two screws securing the CR Board Unit in the Carriage Unit, and take out
the CR Board Unit toward the front.
8.
Remove one screw (CPP: M3×8) securing the CR_ENC ASSY, ground line, and
washer (M3). Then remove the CR_ENC ASSY.
After assembling the CR ENC, the following adjustments should be
A D J U S T M E N T
R E Q U I R E D
made.
"5.1.4.8 CR Encoder Sensor ASSY Adjustment (p.215)"
Disassembly & Assembly
(See Figure 4-37)
(See Figure 4-38)
Disassembly and Assembly of Carriage (CR) Mechanism
Connector
Figure 4-37. CR Encoder Sensor Removal 1/2
Ground line
CR_ENC ASSY
Figure 4-38. CR Encoder Sensor Removal 2/2
Revision A
CR Board Unit
Screw (M3×8)
Ground line
Toothed washer (M3)
178