Removing The Cr Encoder Sensor; Removing The P_Edge Sensor - Epson Stylus Pro 10000 Service Manual

Large format color inkjet printer
Hide thumbs Also See for Stylus Pro 10000:
Table of Contents

Advertisement

EPSON Stylus Pro 10000/10000CF/10600

4.3.3.7 Removing the CR Encoder Sensor

1.
Remove the R Side Cover.
2.
Remove the H Top Cover.
3.
Remove the Carriage Cover.
4.
Disconnect the CR Encoder cable connector from Head Board.
5.
Remove two screws (CPP: M3x8) securing the CR Encoder Sensor, then remove
the CR Encode Sensor.
Figure 4-110. CR Encoder Sensor Removal
When disassemble or reassemble the unit, do not bend or damage
C A U T I O N
the Scale, CR.
When the CR Encoder Sensor or Scale, CR has been replaced or
A D J U S T M E N T
R E Q U I R E D
removed, use the CR_ENC installation gauge to adjust the
installation position. (Refer to Chapter 5 "Adjustment," section
5.3.6)
Disassembly & Assembly
Thank You For Using TheServiceManualShop.com
CR encorder sensor
Scale, CR
Screws
Thank You For Using TheServiceManualShop.com

4.3.3.8 Removing the P_Edge Sensor

1.
Remove the R Side Cover.
2.
Remove the H Top Cover.
3.
Remove the Carriage Cover.
4.
Disconnect the P_Edge Sensor cable connector from Head Board.
5.
Remove one screw (CBP: M3x6) securing the P_Edge sensor and remove the
sensor.
P_Edge sensor
Figure 4-111. P_Edge Sensor Removal
When reassembling the sensor, combine the boss location of the
C A U T I O N
hole of the head base and P_EDGE sensor.
Fix P_EDGE sensor while pushing it towards the platen.
Disassembly
Revision D
Screw
162