Economizer Troubleshooting - Carrier 50PD05 Operating And Service Instructions

Single package displacement ventilation or single zone variable airflow rooftop units electric cooling/gas heating with puron (r-410a) refrigerant and comfortlink 1.x controls
Hide thumbs Also See for 50PD05:
Table of Contents

Advertisement

Economizer
Troubleshooting
Use
the unit
Scrolling
Marquee
display
or a CCN
device
to view
the
economizer
status
display
and
the
economizer
diagnostic
display
(see
Appendix
A)
for
information
on
the
economizer
operation,
Check
the
current
alarms
and
alarm
history
for
any
economizer
alarm
codes
and
correct
any
causes,
(See
Table
11.)
Verify
any
unique
control
configurations
per
installed
site
requirements
or accessories.
If alarms
conditions
are corrected
and
cleared,
operation
of the economizer
may
be verified
by using
the
Service
Test
mode
(see
Service
Test
section
and
Table
5).
The
following
steps
specify
how
to
test
the
economizer
using
the
Scrolling
Marquee
display,
See
Table
11 for
general
economizer
service
analysis.
1. Enter
the Serviee
Test main
menu
on the
display.
2. Enter
TEST
and
turn
ON
test
mode,
A
password
may
be
needed
in order
to turn
ON
the
Service
Test,
The
default
password
is 1111.
3. Return
to the main
level
of Serviee
Test,
4. Enter
the INDP
submenu
and
enter
an initial
value
for
ECON.
This
will
drive
the
economizer
damper
to the
specified
position.
Continue
to adjust the ECON
value
to
make sure the economizer
opens
and closes.
5. Because
of a mechanical
problem
with the economizer,
the
actuator
might
acquire
a new degree
of rotation
which
is
less
than
M.ANG.
If this
occurs,
a "T414
Economizer
Damper
Actuator
Out
of
Calibration"
alert
will
be
generated.
This
alert can only
occur
if the economizer
is
using
digital
conmmnications
(Configuration
--,ECON--,E.CTL
= 1 or 2). The economizer
calibration
procedure
(Serviee
Test-,IND.P-,E.CAL)
will reconfigure
the
actuator
to
the
new
fully
closed
and
fully
open
positions.
To implement
the calibration
procedure,
change
E.CAL
from OFF to ON. E.CAL
will remain
ON as long as
the calibration
procedure
is being
implemented
(as long as 5
minutes).
During
the calibration
procedure
the actuator
will
close
fully
and
then
open
fully.
After
the
calibration
is
complete,
the
degree
of rotation
should
be
greater
than
M.ANG,
causing
the T414
alert to clear. If the T414
alert
does
not
clear,
check
the
economizer
damper
for other
mechanical
problems.
6. Return
to Serviee
Test-+TEST
and turn
OFF
test mode,
This will cause the unit to return to normal operation,
Table 11 -- Economizer
Service
Analysis
PROBLEM
Damper Does Not Move.
Indoor Fan is off.
Economizer
Operation
is Limited
to Minimum
Position.
Economizer
Position
is Less
Than Minimum
Position.
Economizer
Does
Not Return
to Minimum
Position.
Damper
Does Not Close
on Power
Loss.
Outdoor
Damper
Does
Not Fully Close
at 0% or Fully Open at 100%.
Economizer
is not a configured
minimum
position
POSSIBLE CAUSE
Actuator
is unplugged
at motor or at economizer
board.
Unit is not configured
for economizer.
Outdoor-air
temperature
is above economizer
high temperature
lockout.
Outdoor-air
temperature
is below
economizer
low
temperature
lockout.
Communication
loss to economizer
board.
Damper
is jammed.
Minimum
position
is set incorrectly.
Outdoor-air
temperature
is above economizer
high temperature
lockout.
Outdoor-air
temperature
is below
economizer
low temperature
lockout.
Outdoor-air
thermistor
is faulty.
Low suction
pressure
problem
with a compressor.
IAQ is controlling
minimum
damper
position.
Unit is in Unoccupied
mode.
Damper
is jammed.
Unit is operating
under free cooling.
Damper
is jammed
or spring
return is backwards.
Economizer
actuator
is out of calibration.
Unit is operating
under free cooling.
Unit fan speed
is offsetting
the economizer
minimum
position
to maintain
proper ventilation.
REMEDY
Check for proper VFD connections.
Check that
VFD is illuminated
and in Auto mode.
Unit is not configured
for continuous
fan operation
and there are no cooling
or heating
demands.
Unit is in Unoccupied
mode and there is no call for
heating
or cooling.
Tripped
circuit
breaker.
No power to the unit.
Unit is off via CCN command.
Check wiring
connections.
Configure
unit for economizer
per the
instructions.
Adjust
the high temperature
lockout
setting
if it is
incorrect,
otherwise,
economizer
is operating
correctly.
Adjust
the low temperature
lockout
setting
if it is
incorrect,
otherwise,
economizer
is operating
correctly.
Check wiring
connections.
Identify the obstruction
and safely
remove.
Adjust
minimum
position
setting.
Adjust
the high temperature
lockout
setting
if it is incorrect, otherwise,
economizer
is
operating
correctly.
Adjust
the low temperature
lockout
setting
if it is incorrect,
otherwise,
economizer
is
operating
correctly.
Replace
outdoor-air
thermistor.
Economizer
is operating
correctly,
identify
compressor
problem.
Adjust
the IAQ settings
if incorrect,
otherwise,
the economizer
is operating
correctly.
Adjust
unit occupied
schedule
if incorrect,
otherwise,
economizer
is operating
correctly.
Identify the obstruction
and safely
remove.
Economizer
is operating
correctly.
Identify the obstruction
and safely
remove.
Remove
actuator,
flip it over and re-install.
Enter Service Test mode and run the Calibrate
Economizer
(E.CAL) procedure.
Economizer
is operating
correctly.
Economizer
is operating
correctly.
LEGEND
CCN
Carrier Comfort Network
IAQ
Indoor Air Quality
VFD
Variable Frequency Drive
33

Advertisement

Table of Contents
loading

This manual is also suitable for:

48pd0550pd0648pd06

Table of Contents