Carrier 50PD05 Operating And Service Instructions page 77

Single package displacement ventilation or single zone variable airflow rooftop units electric cooling/gas heating with puron (r-410a) refrigerant and comfortlink 1.x controls
Hide thumbs Also See for 50PD05:
Table of Contents

Advertisement

ITEM
TIME
CLOCK
TIME
TIME
DATE
MNTH
DOM
YEAR
DAY
DST
STR.M
STR.W
STR.D
M.ADD
STRM
STRW
STRD
M.SUB
SCH.L
PER.x
OCC.x
UNC.x
MON.x
TUE.x
WED.x
THU.x
FRI.x
SAT.x
SUN.x
HOL.x
(repeat
up to x=8
Periods)
(OCCFECS
= CCN only)
HOL.L
HOL.x
MON.x
DAY.x
LEN.x
(repeat
up to x=9
Holidays)
ITEM
(ALARMDEF
= CCN
only)
(CTLRID
= CCN only)
APPENDIX
A - LOCAL
DISPLAY AND CCN TABLES
(CONT)
EXPANSION
Time of Day
Hour and Minute
Current
Date
Month
of Year
Day of Month
Year
Day of Week
Daylight
Savings
Config.
Start Month
Start Week
Start Day
Minutes
to Add
Stop Month
Stop Week
Stop Day
Minutes
to Subtract
Occupancy
Schedule
Occupancy
Period
x
Occupied
From
Occupied
To
Monday
in Period
Tuesday
in Period
Wednesday
in Period
Thursday
in Period
Friday
in Period
Saturday
in Period
Sunday
in Period
Holiday
in Period
Timed
Override
Hours
Period
x DOW
(MTWTFSSH)
Occupied
From
Occupied
To
Holiday
Schedule
Holiday
x
Holiday
Start Month
Holiday
Start Day
Holiday
Duration
(days)
Table 35 -- MODE
- TIME
CLOCK
RANGE
UNITS
xx.xx
hh.mm
January,
February,
[]
&,
December
1 to31
xxxx
Monday,
Tuesday,
[] &,
Sunday
January,
February,
[]
&,
December
1 to5
1 to7
0 to 90
January,
February,
[]
&,
December
1 to5
1 to7
0 to 90
OO.OO to 23.59
OO.OO to 23.60
Yes/No
Yes/No
Yes/No
Yes/No
Yes/No
Yes/No
Yes/No
Yes/No
hh.mm
hh.mm
x
xxxxxxxx
00.00
to 24.00
00.00
to 24.00
hours
hh.mm
hh.mm
1 to 12 = January
to
December
1 to31
1 to 99
DEFAULT
2
7
6O
11
1
7
6O
00.00
00.00
No
No
No
No
No
No
No
No
00000000
00.00
00.00
CCN
TABLE/SUB-TABLE
CONFIGURATION
TIME
BRODEFS
(continued)
(SCH.L
= Display
only)
OCCDEFCS
HOLIDAY
HOLDYxxS
CCN
POINT
TIME
MOY
DOM
YOCDISP
DOWD!SP
STARTM
STARTW
STARTD
MINADD
STOPM
STO PW
STOPD
MINSUB
PERxOCC
PERxUNC
PERxMON
PERxTUE
PERxWED
PERxTHU
PERxFRI
PERxSAT
PERxSUN
PERxHOL
OVR-
EXT
DOWx
OCCTODx
UNOCTODx
(repeat
up to
x=8 Periods)
HOLMONxx
HOLDAYxx
HOLLENxx
(repeat
up to
xx=30
Holidays)
EXPANSION
Alarm
Routing
Control
Equipment
Priority
Comm
Failure
Retry Time
Re-Alarm
Time
Alarm System
Name
Device
Name:
Description:
Location:
Software
Part Number:
Model
Number:
Serial Number:
Reference
Number:
Table 36 -- CCN
ONLY
TABLES
RANGE
UNITS
00000000
to 11111111
Oto
7
1 to 240
1 to 255
up to 8 alphanum
min
min
48
50
PD
text string
text string
CESR 131459 - XX- XX
DEFAULT
11000000
4
10
18O
48
50
PD
CCN
TABLE/SUB-TABLE
ALARMDEF
CTLR-
I D
CCN POINT
ALRM
CNT
EQP
TYPE
RETRY
TM
RE-ALARM
ALRM
NAM
77