Carrier 50PD05 Operating And Service Instructions page 92

Single package displacement ventilation or single zone variable airflow rooftop units electric cooling/gas heating with puron (r-410a) refrigerant and comfortlink 1.x controls
Hide thumbs Also See for 50PD05:
Table of Contents

Advertisement

AIRFLOW
(Cfm)
1200
1300
1400
1500
1600
1700
1800
1900
2000
AIRFLOW
(Cfm)
1200
1300
1400
1500
1600
1700
1800
1900
2000
LEGEND
Bhp - Brake Horsepower
AIRFLOW
(Cfm)
1500
1600
1700
1800
1900
2000
2100
2200
2300
2400
2500
AIRFLOW
(Cfm)
1500
1600
1700
1800
1900
2000
2100
2200
2300
2400
2500
LEGEND
Bhp - Brake Horsepower
Table 46 -- Fan
Performance
- 48PDF05
Vertical
Units
AVAILABLE EXTERNAL STATIC PRESSURE
(in. wg)
0.2
0.4
Rpm
Bhp
Rpm
Bhp
Rpm
520
0.17
628
0.24
723
545
0.20
648
0.28
739
570
0.24
668
0.32
756
596
0.28
691
0.37
775
623
0.32
714
0.42
795
650
0.37
737
0.48
816
677
0.43
762
0.54
838
705
0.50
787
0.61
861
734
0.57
813
0.68
884
0.6
Bhp
0.33
0.37
0.41
0.46
0.52
0.58
0.65
0.72
0.80
0.8
Rpm
Bhp
811
0.41
823
0.46
837
0.51
853
0.56
870
0.62
889
0.69
909
0.76
929
0.84
951
0.93
1.0
Rpm
Bhp
892
0.51
902
0.56
913
0.61
927
0.67
942
0.73
958
0.80
976
0.88
994
0.97
1014
1.06
1.2
1.4
Rpm
Bhp
Rpm
Bhp
Rpm
968
0.61
1040
0.71
1108
976
0.66
1046
0.77
1112
985
0.72
1054
0.83
1119
996
0.78
1063
0.90
1127
1009
0.85
1074
0.97
1136
1024
0.92
1087
1.05
1147
1039
1.00
1100
1.13
1159
1056
1.09
1116
1.22
1173
1074
1.19
1132
1.32
1188
NOTES:
AVAILABLE EXTERNAL STATIC PRESSURE
(in. wg)
1.8
2.0
1.6
Bhp
Rpm
0.82
1172
0.88
1176
0.95
1181
1.02
1188
1.09
1196
1.17
1205
1.26
1216
1.36
1229
1.46
1242
i. Maxinnml continuous
BHP is 2.0.
2. See General Fan Performance
Notes.
Bhp
Rpm
0.93
1233
1.00
1237
1.07
1241
1.14
1247
1.22
1254
1.31
1262
1.40
1272
1.50
1283
1.61
1295
Bhp
1.04
1.11
1.19
1.27
1.35
1.44
1.54
1.64
1.75
Rpm
593
62O
646
673
7OO
728
755
783
811
84O
868
Table 47 -- Fan Performance - 48PDD06 Vertical Units
0.2
AVAILABLE EXTERNAL STATIC PRESSURE
(in. wg)
0.4
Bhp
Rpm
Bhp
Rpm
0.27
688
0.37
773
0.32
711
0.42
793
0.37
734
0.47
813
0.43
758
0.53
835
0.49
783
0.60
857
0.56
807
0.68
879
0.63
833
0.76
903
0.71
858
0.84
926
0.80
884
0.94
950
0.90
910
1.04
975
1.00
937
1.15
1000
0.6
Bhp
0.46
0.52
0.58
0.64
0.72
0.80
0.88
0.97
1.07
1.18
1.30
Rpm
851
868
886
905
925
946
968
990
1012
1035
1059
0.8
Bhp
0.56
0.62
0.69
0.76
0.84
0.92
1.01
1.11
1.21
1.33
1.45
AVAILABLE EXTERNAL STATIC PRESSURE
(in. wg)
1.2
1.4
Rpm
Bhp
Rpm
Bhp
Rpm
995
0.78
1061
0.89
1125
1007
0.85
1072
0.96
1134
1021
0.92
1084
1.04
1145
1036
1.00
1098
1.13
1157
1053
1.08
1112
1.22
1170
1070
1.18
1128
1.31
1184
1088
1.28
1145
1.42
1199
1107
1.38
1162
1.53
1216
1127
1.50
1181
1.65
1233
1147
1.62
1200
1.77
1251
1168
1.75
1220
1.91
1270
NOTES:
1.6
Bhp
1.01
1.09
1.17
1.26
1.35
1.45
1238
1.56
1253
1.68
1268
1.80
1284
1.93
1300
2.07
1318
i. Maxinnml continuous
BHP is 2.0.
2. See General Fan Performance
Notes.
1.8
Rpm
1186
1194
1203
1214
1226
Bhp
1.14
1.22
1.30
1.39
1.49
1.60
1.71
1.83
1.95
2.09
2.23
1.0
Rpm
Bhp
925
0.67
939
0.73
955
0.80
972
0.88
990
0.96
1009
1.05
1029
1.14
1050
1.24
1071
1.35
1092
1.47
1115
1.60
2.0
Rpm
Bhp
1245
1.26
1252
1.35
1260
1.44
1269
1.53
1280
1.63
1291
1.74
1304
1.86
1318
1.98
1333
2.11
1349
2.25
1365
2.40
92

Advertisement

Table of Contents
loading

This manual is also suitable for:

48pd0550pd0648pd06

Table of Contents