Triton Analog Extension Board
The Triton Analog Extension telephony board has a dedicated voice
channel for every extension port and FSK-only message waiting
The Triton Analog Extension telephony board has the following functional
characteristics:
•
MVIP Compatible
•
256 Port Non-Blocking Switch Matrix
•
Jumper-Free Configuration
•
PCI Bus
•
Compliant with EIA464
•
Recording capability
Note:
When the board is configured for audio input, the first port cannot
be used for an extension.
2-6 AltiContact Manager Administration Manual
LED 1B
LED 1A
ON
ON
OFF
OFF
ON
OFF
OFF
ON
LED 2, located near the 12V connector, is a red LED for diagnostic purposes. If
it is ON, the fuse is blown.
LED Indicators
Status
5V is OK; 12V is OK – normal operation
Power cable not plugged in
5V less than 4.5V but more than 3V – bad PC 5V
power
12V less than 9V – bad PC 12V power
.