Miscellaneous Remote Insight Lights-Out Edition Board Troubleshooting; Keyboard And Mouse - Compaq N2400 - TaskSmart - 1 GB RAM Administration Manual

Administration guide
Table of Contents

Advertisement

Miscellaneous Remote Insight Lights-Out Edition
Board Troubleshooting
The time or date of the entries in the Event Log
are incorrect.
You can update the time and date on the Remote Insight Lights-Out Edition
board by running the System Configuration Utility. This utility automatically
sets the time and date on the board using the server time and date. Compaq
Management Agents for Servers on supported network operating systems also
updates the time and date.
How do you interpret LED error codes?
The LED indicators on the front of the Remote Insight Lights-Out Edition
board (with the LEDs on top) have the following assignments:
FB
7
During the initial start of the Remote Insight Lights-Out Edition board the
LED indicators flash randomly. After the Remote Insight Lights-Out Edition
board is started, the FB LED flashes once a second. The LED indicators (1
through 7) light after start-up to indicate a hardware failure. If a hardware
failure is detected, try resetting the Remote Insight Lights-Out Edition board.
Refer to the Remote Insight Manager Lights-Out Edition User Guide for more
information.
Keyboard and mouse do not work for Remote
Console to the Remote Insight Lights-Out
Edition board.
Verify that the keyboard and mouse cables on the Remote Insight Lights-Out
Edition board are properly installed. (Refer to the Remote Insight Manager
Lights-Out Edition User Guide for more information on connecting the
keyboard cable.)
6
5
4
3
Troubleshooting C-51
2
1
0

Advertisement

Table of Contents
loading