C-50 Compaq TaskSmart N2400 Administration Guide

Troubleshooting Alert and Trap Problems

I am unable to receive Compaq Insight Manager
alarms (SNMP traps) from the Remote Insight
Lights-Out Edition board.
A user with supervisor access must connect to the Remote Insight Lights-Out
Edition board or run the System Configuration Utility to configure SNMP trap
parameters.
1. Make sure the correct alert types are enabled, either in the Manage Alert
Information screen of the Remote Insight Lights-Out Edition board
console application or in the Alerts Received field on the user
information screen in the System Configuration Utility.
2. On the server, run the System Configuration Utility and verify that the
Alerts field is set to Enabled. This field globally enables or disables
alerts for all Remote Insight Lights-Out Edition board users.
3. Verify that the community string and SNMP trap destination is set
correctly on the TaskSmart N2400 SNMP service properties.