Compaq N2400 - TaskSmart - 1 GB RAM Administration Manual page 227

Administration guide
Table of Contents

Advertisement

Activity
Online


CAUTION: Read "Hot-Plug Drive Replacement Guidelines" in the Compaq Servers
Troubleshooting Guide before removing a hard drive.
On
Off
On
Flashing
Flashing
Flashing
Off
Off
Table 6-2
Hard Drive LED Combinations
Indication
Drive Failure

Off
Do not remove the drive. Removing a drive during
this process causes data loss.
The drive is being accessed and is not configured as
part of an array.
Off
Do not remove the drive. Removing a drive during
this process causes data loss.
The drive is rebuilding or undergoing capacity
expansion.
Flashing
Do not remove the drive. Removing a drive during
this process causes data loss.
The drive is part of an array being selected by the
ACU.
-Or-
The Options ROMPaq™ is upgrading the drive.
Off
OK to replace the drive online if a predictive failure
alert is received (see the "Predictive Failure Alert"
section in Compaq Servers Troubleshooting Guide for
details) and the drive is connected to an array
controller.
The drive is not configured as part of an array.
-Or-
If this drive is part of an array, then a powered-up
controller is not accessing the drive.
-Or-
The drive is configured as an online spare.
Advanced Administrative Procedures 6-29
continued

Advertisement

Table of Contents
loading

Table of Contents