8 NXDN CONVENTIONAL SYSTEM
8.7 Sending a Status Message (Status Call)
AUX Input Status Message
Supported Models: Mobile
AUX Input Status Message can be used to send the specified Status Message when the AUX Input port goes high level to
low level or goes low level to high level.
The transceiver can send a Status Message when a sensor is attached to the AUX Input port and the status of the AUX
Input port changes. The target ID is the ID configured for the Base ID. (Refer to
To use this function, AUX Input Status Message must be assigned to one of AUX Input ports.
Configuration using KPG-175D
Configuring the AUX Input Status Message (
Assigning functions to the AUX Input (
AUX Output Status Message
Supported Models: Mobile
AUX Output Status Message is the function to switch the status of the AUX Output port from high to low or from low to high
when the transceiver receives the specified Status Message. This function can be used to remotely turn the external
device On or Off.
To use this function, AUX Output Status Message must be assigned to one of AUX Output ports.
Configuration using KPG-175D
Configuring the AUX Output Status Message (
Assigning functions to the AUX Output (
Storing the Selected or Sent Status (Status Hold)
Supported Models: Mobile
Status Hold is the function to store a sent status in the transceiver.
When the transceiver receives a status request message, the status stored in the transceiver will automatically be
transmitted. Also, the status stored in the transceiver will automatically be stored in GPS data and transmitted.
Configuration
The transceiver stores a status sent by one of the following method:
• A status sent when the status of the AUX Input Status Message port changes.
Enabled
• The status transmitted when the transceiver is turned ON (Power-on Status)
• A status sent by pressing the Call 1 or Call 2 key.
Disabled
The transceiver stores in the transceiver the status configured for Default Status.
Configuration using KPG-175D
Configuring the Status Hold to be enabled or disabled (
FUNC (K)/Ver 1.20
Edit > NXDN > Status)
See
See
Edit > Extended Function > AUX)
Edit > NXDN > Status)
See
Edit > Extended Function > AUX)
See
Table 8-8 Status Hold
Description
Edit > Optional Features > Common 2)
See
Base ID on page
73.)