Kenwood NX-240 Function Reference page 150

Hide thumbs Also See for NX-240:
Table of Contents

Advertisement

10 FleetSync
10.8 Disabling the Transceiver Capability by Remote Control (Stun/ Kill)
10.8
Disabling the Transceiver Capability by Remote Control
(Stun/ Kill)
Stun/ Kill is the function for an administrator to remotely disable the transceiver by using a Remote Stun/ Kill status, for
instance, if the transceiver is stolen. (Refer to
Following is the transceiver behavior when the transceiver receives a Remote Stun/ Kill Status:
Status
The transceiver becomes unable to transmit when the transceiver receives the Remote Stun status (Status 90).
The transceiver becomes unable to transmit and receive when the transceiver receives the Remote Stun status
(Status 91).
Remote Stun
The Stun state is reset when the transceiver receives the Remote Revive status (Status 92).
Whether to accept reception of the Remote Stun status can be configured by using KPG-169D/ KPG-170D/
KPG-175D.
Remote Revive
The Stun state is reset when the transceiver receives the Remote Revive status (Status 92).
The transceiver is disabled and all operations will be prohibited when the transceiver receives the Remote Kill
status (Status 87).
All configuration data of the transceiver is cleared; hence the Stun state will not be reset even if the transceiver
Remote Kill
receives the Remote Revive status (Status 92). However, the configuration data can be written to the transceiver
using KPG-169D/ KPG-170D/ KPG-175D.
Whether to accept reception of the Remote Kill status can be configured by using KPG-169D/ KPG-170D/
KPG-175D.
Note
• GPS data is automatically sent while the transceiver is in Stun state.
• The transceiver cannot be placed in Emergency Mode while the transceiver is in Stun state.
• The LED cannot light or blink while the transceiver is in Stun state.
Configuration using KPG-169D/ KPG-170D/ KPG-175D
Configuring the Stun Status Validation to be enabled or disabled (
Configuring the Kill Status Validation to be enabled or disabled (
FUNC (K)/Ver 1.20
Reserved Statuses of Status Messages on page
Table 10-11 Remote Stun/ Kill Statuses
Description
118)
Edit > FleetSync > General 1)
See
Edit > FleetSync > General 1)
See