19 FUNCTIONS LINKED WITH A VEHICLE
19.2 Controlling Car Behavior by Linking with the Horn Alert Port Status (Horn Alert)
Conditions to Activate the Horn Alert
The conditions to activate the Horn Alert are as follows. The conditions vary between analog and digital (NXDN).
Zone Type
• If the received Optional Signaling matches the Optional Signaling preconfigured for the transceiver while Horn
Conventional
Alert is enabled
Group (Analog)
• If the transceiver receives a Paging Call while Horn Alert is enabled
• If the transceiver receives FleetSync Status 89 regardless of the Horn Alert configuration
• If the received Optional Signaling matches the Optional Signaling preconfigured for the transceiver while Horn
Alert is enabled
• If the transceiver receives a Paging Call while Horn Alert is enabled
Conventional
• If the transceiver receives Horn Alert Status regardless of the Horn Alert configuration
Group (NXDN)
Note
Horn Alert Status can be configured using KPG-175D. (
Horn Alert Logic Signal
Horn Alert Logic Signal is the function to activate the Horn Alert port according to the configuration upon activation of Horn
Alert.
How the Horn Alert port is activated when Horn Alert is activated can be configured using KPG-175D.
Configuration
Until Reset
The Horn Alert port remains active until the matching state of Optional Signaling is reset.
1 s to 30 s
The Horn Alert port remains active for configured amount of time.
The Horn Alert port is activated 3 times at 500-ms intervals.
Pulse
Note
• The Horn Alert port is not deactivated even if the matching state of DTMF and 2-tone is reset, and if the amount of time configured for
the Horn Alert Logic Signal is longer than the length of time configured for the Auto Reset Timer for DTMF or 2-tone. The Horn Alert
port is deactivated when the amount of time configured for Horn Alert Logic Signal elapses.
• Horn Alert is deactivated if one of the following operations is enabled while Horn Alert is activated:
• If the Horn Alert key is pressed (Horn Alert will be disabled)
• If the status of the microphone hook is changed
• If a key is pressed
Configuration using KPG-175D
Configuring the Horn Alert Logic Signal (
FUNC (K)/Ver 1.20
Table 19-1 Conditions to Activate the Horn Alert
Conditions
Table 19-2 Horn Alert Logic Signal
Description
Inactive
500 ms
Active
500 ms
Figure 19-1 Pulse 1
Edit > Optional Features > Common 1 > Horn Alert)
See
See
Edit > NXDN > Status > Option)
500 ms
500 ms
500 ms
CONTENTS
INDEX
190

Advertisement