3.2.5.2
Cleaning the Spray Arm Jets
Spray arm jets should be cleaned and checked at regular intervals. To
remove, take out the baskets and unscrew the spray arms. When re-
fitting, check that the spray arms rotate freely.
3.2.5.3
Cleaning the Drain Pump and the Non-Return Valve
1. Remove the filter combination – refer to Figure 3-17.
2. Release the wire clamp and pull out the non-return valve – refer to
Figure 3-19.
Figure 3-19: Removing the Non-Return Valve
3. The drain pump (refer to Figure 3-20) is situated directly below the
non-return valve. Before re-fitting the valve, check that the impeller
rotates freely and is not blocked by any extraneous objects.
4. Carefully replace the non-return valve and fasten using the wire
clamp.
Figure 3-20: Drain Pump