Miele G500 Technical Information page 73

Table of Contents

Advertisement

G500 Dishwashers
3.2.4.2
Activating Optional Functions on Super Electronic Models
1. Raised water levels
a) Switch the dishwasher off.
b) Press "Short 45°" and "Without Drying" whilst at the same time
c) Press "Universal Plus 65°". A "10" or "11" will appear in the
d) Press "Without Drying" to change "10" to "11" or vice versa.
e) Press "Pre-selection 1-9 hrs"
f) Press "Pre-selection 1-9 hrs" again to store the selected option.
2. Hot air re-circulation drying
a) Switch the dishwasher off.
b) Press "Short 45°" and "Without Drying" whilst at the same time
c) Press "Universal Plus 55°". A "20" or "21" will appear in the
d) Press "Without Drying" to change "20" to "21" or vice versa.
e) Press "Pre-selection 1-9 hrs".
f) Press "Pre-selection 1-9 hrs" again to store the selected option.
switching the dishwasher on. A "P" and an index code will appear
in the display.
display.
"10" = Time-controlled water intake (60 seconds)
"11" = Level-controlled water intake with time limit
"SP" will appear in the display (SP = Memory).
The display will cancel.
switching the dishwasher on. A "P" and an index code will appear
in the display.
display.
"20" = Air extraction
"21" = Air re-circulation
"SP" will appear in the display (SP = Memory).
The display will cancel.
73
Technical Information

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

G570G572G575G579G579scG582sc ... Show all

Table of Contents