Miele G500 Technical Information page 116

Table of Contents

Advertisement

Technical Information
6.1.2.1
Error Message Mode
Figure 6-6: Error Message Mode – 1
1. Switch the machine off.
2. Press "Short 45°" and "Cold" and at the same time switch on the
appliance.
Figure 6-7: Error Message Mode – 2
1. Press "Cold" and "Without drying".
One of the following codes will appear in the digital display:
F0
F1
F2
F3
F4
No fault detected
NTC, sensor leads or temperature controls open-circuited
NTC, sensor leads or temperature controls short-circuited
Defective impulse generator in the electronic unit
Faulty or missing 100 Hz impulse signal
116