5.6
Temperature Limiter 1F2
Remove the plinth panel. The temperature limiter (Figure 5-12, Item 2)
can be accessed once the heater relay (Figure 5-12, Item 1) has been
removed.
5.6.1
Checks on the Temperature Limiter 1F2
Remove the temperature limiter and check the following parameters:
1. The temperature limiter must be marked with "L 83", indicating that it
is intended to cut out at 83°C.
2. The temperature limiter must be fitted as shown in Figure 5-12, Item
2.
Figure 5-12: Temperature Limiter 1F2
107