4 Parameter List
Parameter
No.
Braking Resistor Re-
F52
sistance
Output Terminal [AO]
F58
Filter
Output Terminal [AO]
F59
Bias
F80
Load Mode Selection
4-2-2

Parameter E (Terminal Functions)

Parameter
No.
Input Terminal [DI1]
E01
Function Selection
Input Terminal [DI2]
E02
Function Selection
Input Terminal [DI3]
E03
Function Selection
Input Terminal [DI4]
E04
Function Selection
4-84
Function name
Monitor or Data Range
0.01 to 999 Ω
0.00 to 5.00 s
-100.0 to 100.0 %
0: HHD
1: HND
3: HD (only for 400 V)
4: ND (only for 400 V)
Function name
Monitor or Data Range
0 to 188 normally-open input,
1000 to 1188 normally-close
input
0 to 188 normally-open input,
1000 to 1188 normally-close
input
0 to 188 normally-open input,
1000 to 1188 normally-close
input
0 to 188 normally-open input,
1000 to 1188 normally-close
input
Setting
Default
during
Unit
data
RUN
Availa-
0.01
ohm
ble
Availa-
0.00
s
ble
Availa-
0.0
%
ble
0
-
-
Setting
Default
during
Unit
data
RUN
0
-
-
1
-
-
2
-
-
7
-
-
M1 Series Standard Type User's Manual (I669)
Page
page
5-75
page
7-46
page
7-46
page
5-12
Page
page
7-26
page
7-26
page
7-26
page
7-26

Hide quick links: