7 Other Functions
Pa-
rame-
Item No.
ter
No.
5_06
W67
5_07
W68
5_08
W78
5_09
W81
7-14
Item
Cumulative Run Time
of Capacitors on
0 to 9999 [x10h]
Printed Circuit
Boards
Cumulative Run Time
0 to 9999 [x10h]
of Cooling Fan
0 to 9999
Number of Startups
1000 to 6553 [x10
LED]
Integrated Power
0.000 to 9999
Monitor
[100 kWh]
Range
The time obtained by multiplying the coeffi-
cient based on the ambient temperature con-
ditions with the cumulative time during which
voltage is applied to the electrolytic capaci-
tors on printed circuit boards is displayed as
the cumulative operation time.
Measurement range: 0 to 99,990 hours
Display: 0 to 9999 x10 LED lit
(Cumulative run time of capacitors on printed
circuit boards = Display × 10 hours)
If 99,990 hours is exceeded, the accumula-
tion operation stops, and the display remains
as 9999.
For details, refer to 7-8-10 Capacitor Life
Warning Signal (WAC) on page 7-96.
The cumulative time when the cooling fan
was operating is displayed.
Counting is not performed when the ON/OFF
control effective (parameter H06) is enabled,
and the cooling fan has stopped.
Measurement range: 0 to 99,990 hours
Display: 0 to 9999 x10 LED lit
(Cumulative run time of cooling fan = Display
× 10 hours)
If 99,990 hours is exceeded, the accumula-
tion operation stops, and the display remains
as 9999.
The number of operations of the 1st motor
(number of times the RUN command for the
inverter is turned ON) is calculated and dis-
played. If the number of operations becomes
10,000 or more, the x10 LED lights up and
the value of "Number of operations/10" is dis-
played. If 65,530 operations is exceeded, the
value returns to 0 and the calculation contin-
ues.
The integrating electric power consumption is
displayed. 0.1 kWh to 999,900 kWh is dis-
played for 0.001 to 9999, with 1 = 100 kWh.
The value returns to 0 at 1,000,000 kWh.
The integrated electric power consumption
and the integrated electric power data can be
reset by setting Display Coefficient for Inte-
grated Power (E51) to "0.000." If 999,900
kWh is exceeded, the value returns to 0. Inte-
gration is not performed when 0.000 is still
set.
M1 Series Standard Type User's Manual (I669)
Display item