Omron M1 Series User Manual page 512

Multi-function compact inverter
Hide thumbs Also See for M1 Series:
Table of Contents

Advertisement

7 Other Functions
Item
Parameter
No.
No.
X31,
6_12
X32
6_13
X31
6_14
X32
6_15
X00
6_16
X01
6_17
X02
X33,
6_18
X34
6_19
X33
7-20
Item
Latest Alarm Info. In-
put Terminal, Latest
Alarm Info. Output
LED4 LED3 LED2 LED1
Terminal
(Display depending
on whether each seg-
ment of the LED is
ON or OFF.)
Latest Alarm Info. In-
0000Hex to
put Terminal
FFFFHex
(Hexadecimal display)
Latest Alarm Info.
0000Hex to
Output Terminal
FFFFHex
(Hexadecimal display)
Latest Alarm History/
Number of Consecu-
0 to 255
tive Same Alarms
Latest Multiple
Alarm code display
Alarm1
Latest Multiple
Alarm code display
Alarm2
Latest Alarm Info. In-
put Terminal via Com-
munication, Latest
Alarm Info. Output
LED4 LED3 LED2 LED1
Terminal via Commu-
nication
(Display depending
on whether each seg-
ment of the LED is
ON or OFF.)
Latest Alarm Info. In-
put Terminal via Com-
0000Hex to
munication
FFFFHex
(Hexadecimal display)
Range
The final command value of the terminal
block I/O signal when an alarm occurs is
displayed by lighting on the segment dis-
play. The display format is the same as
the expression of I/O check. (Refer to
7-1-2 I/O check on page 7-11.)
The final command value of the terminal
block input signal when an alarm occurs
is displayed by a four-digit hexadecimal.
The display format is the same as the
expression of I/O check. (Refer to
7-1-2 I/O check on page 7-11.)
The final command value of the terminal
block output signal when an alarm oc-
curs is displayed by a four-digit hexadec-
imal.
The display format is the same as the
expression of I/O check. (Refer to
7-1-2 I/O check on page 7-11.)
Displays the number of times the same
alarm occurred continuously. When the
same alarm occurs continuously, the
number of continuous occurrences is up-
dated, and the oldest data is recorded to
the last alarm and the newest data is re-
corded to the newest alarm.
Simultaneously occurring alarm code
(1st) when a main alarm occurred or
while it is occurring
("----" is displayed if no alarm occurs si-
multaneously)
Simultaneously occurring alarm code
(2nd) when a main alarm occurred or
while it is occurring
("----" is displayed if no alarm occurs si-
multaneously)
The final command value of the commu-
nication I/O signal when an alarm occurs
is displayed by lighting on the segment
display. The display format is the same
as the expression of I/O check. (Refer to
7-1-2 I/O check on page 7-11.)
The final command value of the commu-
nication input signal when an alarm oc-
curs is displayed by a four-digit hexadec-
imal.
M1 Series Standard Type User's Manual (I669)
Description

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents