Omron M1 Series User Manual page 441

Multi-function compact inverter
Hide thumbs Also See for M1 Series:
Table of Contents

Advertisement

Parame-
ter No.
Torque Bias Function
H154
Selection
Torque Bias Level 1
H155/
H156/
Torque Bias Level 2
H157
Torque Bias Level 3
Torque Bias Mechanical
H158
Loss Compensation
Torque Bias Startup
H159
Timer
Torque Bias Shutdown
H161
Timer
H162
Torque Bias Limit
Torque Bias Polarity
H334
Selection
Torque Bias Value via
S15
Communication
Torque Bias Value
S24
(MX2 compatible)
Input Terminal [DI1]
E01 to
Function Selection to
E05, E98,
Input Terminal [DI7]
E99
Function Selection
M1 Series Standard Type User's Manual (I669)
Function name
0: Invalid
1: Operator (H155 to H157)
2: Analog input
4: RS-485 communication
5: Fieldbus (Reserved)
-300 to +300 %
0 to 300
0.00 to 1.00
0.00 to 1.00
0 to 300
0: Signed
1: Depends on the run direction
-327.68 to 327.67
-327 to +327
(Truncate to S15 set value)
60: TB1 (Torque bias command 1)
61: TB2 (Torque bias command 2)
62: H-TB (Torque bias hold)
6 Vector Control and Applied Functions
Data
Default
Unit
data
0
-
0
%
0
%
0.00
s
0.00
s
200
%
0
-
0.00
%
0
%
6
-
-
6-35