6 Vector Control and Applied Functions
6-10 Application Control
In winding systems such as wire drawing machines and spinning machines, the outer diameter of the
wind-up roll increases due to the amount of material being wound onto the roll and the actual wind-up
speed increases when winding is continued at a constant shaft speed. To maintain the wind-up speed
at the outer periphery at a constant speed, a speed sensor is used to detect the wind-up speed, and
the speed of the motor shaft is controlled so that the wind-up speed is kept constant.
6-10-1
Application Control Settings
Set enable/disable status for line speed control and synchronized run operation (simultaneous start
synchronization/standby synchronization).
Parameter
No.
d41
d15
d16
d17
E01 to E05,
E98, E99
Machine Configuration and Settings
The following parameters must be set when the mechanical system of a winder is configured as
shown in the figure below.
6-78
Function name
Special Control Selec-
1: Line speed control with speed sen-
tion
sor
Input Terminal [PIA][PIB]
Encoder Pulse Resolu-
20 to 60000
tion
Input Terminal [PIA][PIB]
Pulse Scaling Factor
1 to 32767
Denominator
Input Terminal [PIA][PIB]
Pulse Scaling Factor
1 to 32767
Numerator
Input Terminal [DI1]
70: Line speed control cancellation
Function Selection to In-
71: Line speed control frequency
put Terminal [DI7] Func-
memory
tion Selection
Data
Default data
M1 Series Standard Type User's Manual (I669)
Unit
0
-
1024
Pulse
1
-
1
-
-
-

Hide quick links:

Advertisement

Table of Contents
loading