Parameter
No.
E20, E21
E27
Related function
Forward Run Signal (FWR)
• This signal is output while the inverter performs forward operation.
• To output this signal, allocate "52: FWR (Forward run signal)" to Output Terminal [DO1] Function Se-
lection (E20), Output Terminal [DO2] Function Selection (E21) or Output Terminal [ROA, ROB]
Function Selection (E27).
Parameter
No.
E20, E21
E27
• This signal is not output while the inverter performs reverse operation, when it is stopped or during
free-run. Note, however, that during control methods with sensor, judgment is performed based on
the speed detection value to output the signal even in free-run status.
Reverse Run Signal (RVR)
• This signal is output while the inverter performs reverse operation.
• To output this signal, allocate "53: RVR (Reverse run signal)" to Output Terminal [DO1] Function Se-
lection (E20), Output Terminal [DO2] Function Selection (E21) or Output Terminal [ROA, ROB]
Function Selection (E27).
Parameter
No.
E20, E21
E27
M1 Series Standard Type User's Manual (I669)
Function name
Output Terminal [DO1] Function Selection,
Output Terminal [DO2] Function Selection
Output Terminal [ROA, ROB] Function Se-
lection
Fig. OFF when at stop frequency and starting frequency or below
Function name
Output Terminal [DO1] Function Selection,
Output Terminal [DO2] Function Selection
Output Terminal [ROA, ROB] Function Se-
lection
Function name
Output Terminal [DO1] Function Selection,
Output Terminal [DO2] Function Selection
Output Terminal [ROA, ROB] Function Se-
lection
Data
Default data
0: RUN (Signal dur-
ing RUN)
35: RUN2 (Inverter
output in progress)
ON
OFF
ON
OFF
Data
Default data
52: FWR (Forward
run signal)
Data
Default data
53: RVR (Reverse
run signal)
5 Basic Settings
Unit
-
-
99
-
5
Unit
-
-
99
Unit
-
-
99
5-69