Omron M1 Series User Manual page 390

Multi-function compact inverter
Hide thumbs Also See for M1 Series:
Table of Contents

Advertisement

5 Basic Settings
• A smaller number is sometimes selected for the frequency reference depending on the timing of
switching.
Jogging (JG)
The jogging function operates according to the jogging terminal (10: JG) and RUN command (FW or
RV terminal), or forward rotation jogging terminal (94: FJOG) and reverse rotation jogging terminal (95:
RJOG). The jogging function can also be enabled from the Operator.
• Jogging terminal (10: JG) and RUN command (FW or RV terminal)
• Forward rotation jogging terminal (94: FJOG) and reverse rotation jogging terminal (95: RJOG)
• Jogging function startup from Operator
• Jogging execution via communication
• Jogging frequency (C20), acceleration time (H54) and deceleration time (H55) of jogging operation
can be set. Select jogging operation at start and stop of jogging at Jogging Operation Selection
(E111).
• During position control, jogging operation is disabled.
• Speed control during jogging operation can be adjusted by filter, gain, etc.
Parameter
No.
Input Terminal [DI1] Func-
E01 to E05,
tion Selection to Input Ter-
E98, E99
minal [DI7] Function Selec-
tion
5-60
Multi-step frequency reference 0
4th
5th
6th
7th
3rd
2nd
1st
0 Hz
Function name
10: JG (Jogging)
94: Forward rotation jogging
95: Reverse rotation jogging
Data
Default data
M1 Series Standard Type User's Manual (I669)
Unit
-
-

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents