Item
Parameter
No.
No.
6_07
X66
6_09
X68
6_30
X118
3 Second last alarm
6_00
Z00
6_01
Z01
6_06
Z05
6_07
Z06
6_09
Z08
6_30
X128
4 Third last alarm
6_00
Z50
6_01
Z51
6_06
Z55
M1 Series Standard Type User's Manual (I669)
Item
Last Alarm Info. Cu-
0 to 655,350 hours
mulative Ope. Time
Last Alarm Info. Main
0.0 to 999.0 [V]
Circuit DC Voltage
Last Alarm Info. Cu-
mulative Running
0 to 655,350 hours
Time
Second Last Alarm
0.00 to 99.99,
Info. Output Frequen-
100.0 to 590.0 [Hz]
cy
Second Last Alarm
0.00 to 99.99,
Info. Output Current
100.0 to 655.3 [A]
Second Last Alarm
0000Hex to
Info. Running Status
FFFFHex
Second Last Alarm
Info. Cumulative Ope.
0 to 655,350 hours
Time
Second Last Alarm
Info. Main Circuit DC
0.0 to 999.0 [V]
Voltage
Second last Alarm In-
fo. Cumulative Run-
0 to 655,350 hours
ning Time
Third Last Alarm Info.
0.00 to 99.99,
Output Frequency
100.0 to 590.0 [Hz]
Third Last Alarm Info.
0.00 to 99.99,
Output Current
100.0 to 655.3 [A]
Third Last Alarm Info.
0000Hex to
Running Status
FFFFHex
Range
The number of operations of the motor
(number of times the RUN command for
the inverter is turned ON) is calculated
and displayed.
The Main Circuit DC Voltage of the inver-
ter is displayed.
The cumulative time of the inverter RUN
state is displayed.
The cumulative operation time is dis-
played alternately in the upper digits and
lower digits.
When the lower three digits are dis-
played, an h (hours) is displayed in the
lowermost digit.
The output frequency before slip com-
pensation is displayed in increments of
0.01 Hz. A value of 100.0 Hz or higher is
displayed in increments of 0.1 Hz.
The output current is displayed. A cur-
rent value of 100.0A or higher is dis-
played in increments of 0.1 A.
Display unit: A (Ampere)
The operation status is displayed by a
four-digit hexadecimal.
The number of operations of the motor
(number of times the RUN command for
the inverter is turned ON) is calculated
and displayed.
The Main Circuit DC Voltage of the inver-
ter is displayed.
The cumulative time of the inverter RUN
state is displayed.
The cumulative operation time is dis-
played alternately in the upper digits and
lower digits.
When the lower three digits are dis-
played, an h (hours) is displayed in the
lowermost digit.
The output frequency before slip com-
pensation is displayed in increments of
0.01 Hz. A value of 100.0 Hz or higher is
displayed in increments of 0.1 Hz.
The output current is displayed. A cur-
rent value of 100.0A or higher is dis-
played in increments of 0.1 A.
Display unit: A (Ampere)
The operation status is displayed by a
four-digit hexadecimal.
7 Other Functions
Description
7-23